Calibration and Settings Sheet  for AccuLoad LTWS Hydraulic Weighing Systems with TI-500 Indicator
Date _________________     S/N  ________________  Test Weight  _______________  (Pounds) (Kilos)

 
"F" Number
Preset
Field
Comments
F1
500   Graduations full scale
F2
25   SPAN Gain
F3
3   ZERO tracking Band
F4
100   ZERO Range %
F5
3   Motion Band between samples
F6
8   Digital Filter (Averages)
F7
2   Overload Limit (Full Scale %)
F8
1   Display "lb" or "kg"
F9
5   Display Increment Units
F10
00   Display Increments - Decimals
F16
See Note - Ref. Only Ask Tech Support Lift empty forks/bucket, Press "ZERO", Press "SET"
F17
N/A   Enter Test Weight - Lift  Weight - Press "SET"
F18
N/A   CAL 0 -"ZERO" Empty Fork/Bucket reference
F18
N/A   CAL 1 - "SPAN" Test Weight reference
F19
N/A    Manual ZERO reference Entry
F20
N/A    Manual SPAN reference Entry
F21
DO NOT USE Consult Manual Factory Reset all settings
A12
53   Set Number of Stable Reading